Toplam 7 içerik listeleniyor
-
Vacuubrand MD 12C NT +EK
Technical data Unit Converter Technical dataUnitMD 12C NT +EK Number of heads / stages 8 / 3 Max. pumping speed at 50/60 Hz m3/h 12.0 / 13.3 Max. pumping speed at 50/60 Hz cfm 7.1 / 7.8 Ultimate vacuum (abs.) mbar/torr 2 / 1.5 Ultim. vac. (abs.) with gas ballast mbar/torr 4 / 3 Ambient temperature range (operation) °C 10 - 40 Ambient temperature range (storage) °C -10 - 60 Max. back pressure (abs.) bar 1.1 Inlet...
https://www.sesim.com.tr/vacuubrand-md-12c-nt-ek
-
Vacuubrand MD 12C NT +AK+EK
Technical data Unit Converter Technical dataUnitMD 12C NT +AK+EK Number of heads / stages 8 / 3 Max. pumping speed at 50/60 Hz m3/h 12.0 / 13.3 Max. pumping speed at 50/60 Hz cfm 7.1 / 7.8 Ultimate vacuum (abs.) mbar/torr 2 / 1.5 Ultim. vac. (abs.) with gas ballast mbar/torr 4 / 3 Ambient temperature range (operation) °C 10 - 40 Ambient temperature range (storage) °C -10 - 60 Max. back pressure (abs.) bar 1.1 Inlet...
https://www.sesim.com.tr/vacuubrand-md-12c-nt-ak-ek
-
VACUUBRAND VARIO® PC 3012 NT VARIO DUO
Technical data Unit Converter Technical dataUnitPC 3012 NT VARIO DUO Vacuum controller CVC 3000 Number of heads / stages 16 / 3 Max. pumping speed m3/h 28 Max. pumping speed cfm 16.5 Ultimate vacuum (abs.) mbar/torr 1.5 / 1.1 Ultim. vac. (abs.) with gas ballast mbar/torr 3 / 2.2 Ambient temperature range (operation) °C 10 - 40 Ambient temperature range (storage) °C -10 - 60 Max. back pressure...
https://www.sesim.com.tr/vacuubrand-vario-pc-3012-nt-vario-duo
-
Nutch Filtreleri
Filtration in general from NORMAG – either as a fixed or flexible mobile nutch filter unit – are provided since decades as central partner of the chemical & pharmaceutical for lab & process scale. Based on this long-term experience we can offer: lab&process scale fixed & mobile nutch filter Chemical Engineering design & scale up together with MAVAG specific internals from NORMAG and MAVAG corrosion resistant materials incl. Boro 3.3,...
https://www.sesim.com.tr/nutch-filtreleri
-
LAUDA HKS Industrial Heating and Cooling Systems
Accurate temperature control is accomplished by either supplying or removing thermal energy to a product, a vessel or process. The medium used to transport the energy must be flexible—with a wide operating temperature range and a good specific heat transfer capacity. Gaseous and solid mediums are not as suitable for combined heating and cooling applications so those heat transfer mediums tend to be liquid based. As these fluids transport thermal energy they are also known as liquid heat...
https://www.sesim.com.tr/lauda-hks-industrial-heating-and-cooling-systems
-
Secondary Circuit Systems
Secondary circuit systems make use of thermal energy from existing steam, thermal oil, cooling water and cooling brine networks. The control facilitates the automatic extraction of the energy required for heating and cooling from the primary system (via heat exchanger or by the direct injection of the heat transfer fluid). Series TR (all systems can also be supplied with explosion protection.) Technical features TR 150 TR 250 TR 350 TR 400 TR 600 Heat transfer...
https://www.sesim.com.tr/secondary-circuit-systems
-
Apart Yüksek Basınçlı Reaktörler
Thus, they get up to speed!With "apart", you are always well received! Then the clever compact convinces with intelligent ideas for equipment and technology. A 24 V/DC motor and a magnetic coupling with a torque of 20-50 Ncm provide dynamic drive.Also the speed of up to 1150 rpm is very respectable, depending on the revs per minute, a ball bearing or friction bearing is offered. Naturally, you select the bearing depending on your medium. The low maintenance sequence is not only comfortable in...
https://www.sesim.com.tr/apart-yuksek-basincli-reaktorler